Joint Stock Company 'United Space Device Corporation' Tell thanksTell thanks ClaimClaim Ask a questionAsk a question
buy on-line sitemap home
 
 
ABOUT THE COMPANY
 
OUR EQUIPMENT
 
EHF- THERAPY
 
MIL-THERAPY
 
 
 
 
 








Home / Price-list


Price-list




Effective as on 01.09.2017yr.
Stock-keeping unit (SKU) Name Description Price, Euro
 
 
PHYSIOTHERAPY
 
 
Laser physiotherapy
 
 
Devices for magnetic-laser therapy"MILTA-F-8-01"
 
101001 Device "MILTA-F-8-01"
5-7 W (watt)
Double-tubes device for magnetic-laser therapy with one emitting terminal
Pulse power of IR-laser radiation57 W
Intensity of continuous IR-light-emitting-diode radiation- 100 mW (milliwatt)
Magnetic induction - 30 mT (millitesla)
483,06
101002 Device "MILTA-F-8-01"
7-9 W (watt)
Double-tubes device for magnetic-laser therapy with one emitting terminal
Pulse power of IR-laser radiation 79 W
Intensity of continuous IR-light-emitting-diode radiation- 100 mW (milliwatt)
Magnetic induction - 30 mT (millitesla)
542,82
101003 Device "MILTA-F-8-01"
9-12 W (watt)
Double-tubes device for magnetic-laser therapy with one emitting terminal
Pulse power of IR-laser radiation 912 W
Intensity of continuous IR-light-emitting-diode radiation- 100 mW (milliwatt)
Magnetic induction - 30 mT (millitesla)
602,58
101004 Device "MILTA-F-8-01"
12-15 W (watt)
Double-tubes device for magnetic-laser therapy with one emitting terminal
Pulse power of IR-laser radiation 1215 W
Intensity of continuous IR-light-emitting-diode radiation- 100 mW (milliwatt)
Magnetic induction - 30 mT (millitesla)
654,04
101005 Device "MILTA-F-8-01"
15-18 W (watt)
Double-tubes device for magnetic-laser therapy with one emitting terminal
Pulse power of IR-laser radiation 1518 W
Intensity of continuous IR-light-emitting-diode radiation- 100 mW (milliwatt)
Magnetic induction - 30 mT (millitesla)
733,72
101006 Device "MILTA-F-8-01"
18-21 W (watt)
Double-tubes device for magnetic-laser therapy with one emitting terminal
Pulse power of IR-laser radiation 1821 W
Intensity of continuous IR-light-emitting-diode radiation- 100 mW (milliwatt)
Magnetic induction - 30 mT (millitesla)
825,02
101007 Device "MILTA-F-8-01" (expanded limitations of diagnosis-1)
5-7 W (watt)
Double-tubes device for magnetic-laser therapy with one emitting terminal
Pulse power of IR-laser radiation 57 W
Intensity of continuous IR-light-emitting-diode radiation- 100 mW (milliwatt)
Magnetic induction - 30 mT (millitesla)
Two photometers allow to receive data of biophotometry both from skin integument, and from internal tissues.
521,24
101008 Device "MILTA-F-8-01" (expanded limitations of diagnosis-2)
7-9 W (watt)
Double-tubes device for magnetic-laser therapy with one emitting terminal
Pulse power of IR-laser radiation 79 W
Intensity of continuous IR-light-emitting-diode radiation- 100 mW (milliwatt)
Magnetic induction - 30 mT (millitesla)
Two photometers allow to receive data of biophotometry both from skin integument, and from internal tissues.
609,22
101009 Device "MILTAF-8-01" (expanded limitations of diagnosis-3)
9-12 W (watt)
Double-tubes device for magnetic-laser therapy with one emitting terminal
Pulse power of IR-laser radiation 912 W
Intensity of continuous IR-light-emitting-diode radiation - 100 mW (milliwatt)
Magnetic induction - 30 mT (millitesla)
Two photometers allow to receive data of biophotometry both from skin integument, and from internal tissues.
657,36
101010 Device "MILTA-F-8-01" (expanded limitations of diagnosis-4) Double-tubes device for magnetic-laser therapy with one emitting terminal
Pulse power of IR-laser radiation 1215 W
Intensity of continuous IR-light-emitting-diode radiation- 100 mW (milliwatt)
Magnetic induction - 30 mT (millitesla)
Two photometers allow to receive data of biophotometry both from skin integument, and from internal tissues.
707,16
101011 Device "MILTA-F-8-01"(expanded limitations of diagnosis-5)
15-18 W (watt)
Double-tubes device for magnetic-laser therapy with one emitting terminal
Pulse power of IR-laser radiation 1518 W
Intensity of continuous IR-light-emitting-diode radiation- 100 mW (milliwatt)
Magnetic induction - 30 mT (millitesla)
Two photometers allow to receive data of biophotometry both from skin integument, and from internal tissues.
788,5
101012 Device "MILTA-F-8-01"(expanded limitations of diagnosis-6)
18-21 W (watt)
Double-tubes device for magnetic-laser therapy with one emitting terminal
Pulse power of IR-laser radiation 1821 W
Intensity of continuous IR-light-emitting-diode radiation- 100 mW (milliwatt)
Magnetic induction - 30 mT (millitesla)
Two photometers allow to receive data of biophotometry both from skin integument, and from internal tissues.
866,52
 
Ancillary emitting terminals to devices "MILTA-F-8-01"
 
101013 DT-1
5-7 W
Pulse power of IR-laser radiation 57 W
Intensity of continuous IR-light-emitting-diode radiation - 100 mW (milliwatt)
Magnetic induction - 30 mT (millitesla)
119,52
101014 DT-2
7-9 W
Pulse power of IR-laser radiation 79 W
Intensity of continuous IR-light-emitting-diode radiation - 100 mW (milliwatt)
Magnetic induction - 30 mT (millitesla)
157,7
101015 DT-3
9-12 W
Pulse power of IR-laser radiation 912 W
Intensity of continuous IR-light-emitting-diode radiation - 100 mW (milliwatt)
Magnetic induction - 30 mT (millitesla)
177,62
101016 DT- 4
12-15 W
Pulse power of IR-laser radiation 1215 W
Intensity of continuous IR-light-emitting-diode radiation- 100 mW (milliwatt)
Magnetic induction - 30 mT (millitesla)
187,58
101017 DT- 5
15-18 W
Pulse power of IR-laser radiation 1518 W
Intensity of continuous IR-light-emitting-diode radiation - 100 mW (milliwatt)
Magnetic induction - 30 mT (millitesla)
212,48
101018 DT- 6
18-21 W
Pulse power of IR-laser radiation 1821 W
Intensity of continuous IR-light-emitting-diode radiation - 100 mW (milliwatt)
Magnetic induction - 30 mT (millitesla)
234,06
101019 KT-1
5-7 W
Pulse power of IR-laser radiation 57 W
Intensity of continuous red-light-emitting-diode radiation- 50 mW (milliwatt)
Magnetic induction - 30 mT (millitesla)
141,1
101020 KT-2
7-9 W
Pulse power of IR-laser radiation 79 W
Intensity of continuous red-light-emitting-diode radiation- 50 mW (milliwatt)
Magnetic induction - 30 mT (millitesla)
157,7
101021 -3
9-12 W
Pulse power of IR-laser radiation 912 W
Intensity of continuous red-light-emitting-diode radiation- 50 mW (milliwatt)
Magnetic induction - 30 mT (millitesla)
177,62
101022 - 4
12-15 W
Pulse power of IR-laser radiation 1215 W
Intensity of continuous red-light-emitting-diode radiation- 50 mW (milliwatt)
Magnetic induction - 30 mT (millitesla)
195,88
101023 - 5
15-18 W
Pulse power of IR-laser radiation 1518 W
Intensity of continuous red-light-emitting-diode radiation - 50 mW (milliwatt)
Magnetic induction - 30 mT (millitesla)
220,78
101024 - 6
18-21 W
Pulse power of IR-laser radiation 1821 W
Intensity of continuous red-light-emitting-diode radiation- 50 mW (milliwatt)
Magnetic induction - 30 mT (millitesla)
245,68
101025 MT Ancillary emitting terminal of matrical type (laser shower).
Pulse power of IR-laser radiation 60 W
Intensity of continuous IR-light-emitting-diode radiation- 150 mW (milliwatt)
Magnetic induction - 30 mT (millitesla)
258,96
101026 MVT Matrical intracavitary terminal for theuse in urinology.
Pulse power of IR-laser radiation 12 W
156,04
101027 DT-VLOK Intensity of continuous red(0,63 micrometer) laser radiation - 2,5 mW (milliwatt) (1,5mW at the exit from lightguide) 146,08
101028 DT - VLOK - M Intensity of continuous red (0,63 micrometer) laser radiation - 30 mW (milliwatt) (15 mW at the exit from lightguide) 411,68
101029 Terminal of extremely high-frequency therapy Millimeter waves of extremely high-frequency 7.1, 5.6, 4.9 mm (millimeter).
Power flux density 4-12 mW/cm2
544,48
 
Lightguide nozzles and complete equipment to devices "MILTA-F-8-01"
 
101030 Set of Lightguide nozzles No1(7 pcs.) Gynecology (2 pcs. - NoNo1 2), urinology (No3), otorhinolaryngology (No4), stomatology (No5), acupuncture (No6), dermatology and cosmetology (No7). 132,8
101031 Set of Lightguide nozzles No2 (6 pcs.) Stomatology (2 pcs. - NoNo 8 9), mammology (No10), gynecology (No11), urinology and proctology (No12), dermatology and cosmetology (No7). 127,82
101032 Set of nozzles for obstetric and gynecology 6 pcs. different kinds (NoNo 1, 2, 3, 7, 10, 11). 116,2
101033 Set of nozzles forstomatology 4 pcs. different kinds(NoNo 5, 7, 8, 9). 83
101034 Set of nozzles for urinology and proctology 4 pcs. different kinds (NoNo 3, 4, 7, 12). 79,68
101035 Set of nozzles forotorhinolaryngology 5 pcs. different kinds (NoNo 4, 7, 13, 14, 15). 102,92
101036 Lightguide nozzle No1 Gynecology for treatment of diseases of cervix uteri (intravaginal) 24,9
101037 Lightguide nozzle No2 Gynecology for treatment of diseases of sheath 24,9
101038 Lightguide nozzle No3 Urinology, Gynecology for treatment of diseases of sheath 24,9
101039 Lightguide nozzleNo4 Otorhinolaryngology for conduction of laser radiation to tonsils 24,9
101040 Lightguide nozzle No5 Stomatology for treatment of dental disorder,diseases of gingivae and mouth cavity 24,9
101041 Lightguide nozzleNo6 Acupuncture for laser reflexotherapy 24,9
101042 Lightguide nozzle No7 Dermatology, cosmetology and hygiene of procedures 11,62
101043 Lightguide nozzle No8 Stomatology for treatment of dental disorder,diseases of gingivae and mouth cavity 24,9
101044 Lightguide nozzle No9 Stomatology for treatment of periodontitis 24,9
101045 Lightguide nozzle No10 Mammology 24,9
101046 Lightguide nozzle No11 Gynecology forpercutaneous intervention 28,22
101047 Lightguide nozzleNo12 Urinology, proctology for ray treatment of prostate gland and parietes ofrectum 24,9
101048 Lightguide nozzle No13 Otorhinolaryngology for conduction of laser radiation to tonsils 24,9
101049 Lightguide nozzle No14 Otorhinolaryngology for endo-auricular intervention and conduction of laser radiation to tympanic membrane and forintranasal intervention in pediatrics 24,9
101050 Lightguide nozzle No15 Otorhinolaryngology forintranasa intervention and in pediatrics 24,9
101051 Proper eye protection "BIOLASER" Frame googles for protection from laser radiation. Modern design, adjustable arms. IR, red, green, blue, ultraviolet irradiation. 32,37
101052 Proper eye protection "ZN-22 "Matriks" Safety spectacles, modern design. Red and ultraviolet irradiation. 26,56
101053 Proper eye protection for patient Light and convenient opaque glasses made from plastic. 29,05
101054 Support-holder It provides fixation of emitting terminal over laser-illuminated surface 19,92
101058 Bag-compartmented trunk Convenient and compact bag for storage and carrying of the device "MILTA-F-8-01" with partition for ancillary emitters, component parts and books. 66,4
101059 Laser emmitter IPLI 101/120 Semi-conductinglaser emmitter of pulse operation.Wavelength - 0,89 micrometer. Pulse power of laser radiation = 5-20 W 43,16
101060 Laser emmitter IPLI 120/120 Semi-conductinglaser emmitter of pulse operation.Wavelength - 0,89 micrometer. Pulse power of laser radiation = 20-35 51,46
 
Devices for magnetic-light-laser therapy "MILTA-F-5-01"
 
101061 Device "MILTA-F-5-01"
5-7 W
Pulse power of IR-laser radiation 57 W
Intensity of continuous IR-light-emitting-diode radiation- 100 mW (milliwatt)
Magnetic induction - 30 mT (millitesla)
Line supply
Guaranty for device 5 years as from the date of sale!
260,62
101062 Device "MILTA-F-5-01" ()
5-7 W
Pulse power of IR-laser radiation 57 W
Intensity of continuous IR-light-emitting-diode radiation- 100 mW (milliwatt)
Magnetic induction - 30 mT (millitesla)
Battery supply
Guaranty for device 5 years as from the date of sale!
272,24
101063 Device "MILTA-F-5-01"
7-9 W
Pulse power of IR-laser radiation 79 W
Intensity of continuous IR-light-emitting-diode radiation- 100 mW (milliwatt)
Magnetic induction - 30 mT (millitesla)
Line supply
Guaranty for device 5 years as from the date of sale!
292,16
101064 Device "MILTA-F-5-01" ()
7-9 W
Pulse power of IR-laser radiation 79 W
Intensity of continuous IR-light-emitting-diode radiation- 100 mW (milliwatt)
Magnetic induction - 30 mT (millitesla)
Battery supply
Guaranty for device 5 years as from the date of sale!
302,12
101065 Device "MILTA-F-5-01"
9-12 W
Pulse power of IR-laser radiation 912 W
Intensity of continuous IR-light-emitting-diode radiation- 100
Magnetic induction - 30 mT (millitesla)
Line supply
Guaranty for device 5 years as from the date of sale!
338,64
101066 Device "MILTA-F-5-01" ()
9-12 W
Pulse power of IR-laser radiation 912 W
Intensity of continuous IR-light-emitting-diode radiation- 100 mW (milliwatt)
Magnetic induction - 30 mT (millitesla)
Battery supply
Guaranty for device 5 years as from the date of sale!
353,58
101068 Device "MILTA-F-5-01" (BIO)
0-10 W
Adjustable pulse power of laser radiation 0-10 W.
Intensity of continuous blue-light-emitting-diode radiation- 10 mW (milliwatt)
Intensity of continuous red-light-emitting-diode radiation- 5 mW (milliwatt)
Intensity of continuous IR-light-emitting-diode radiation - 50 mW (milliwatt)
Magnetic induction - 30 mT (millitesla)
Guaranty for device 5 years as from the date of sale!
454,84
101069 Device "MILTA-F-5-01" (BIO)
0-14 W
Adjustable pulse power of laser radiation 0-14 W.
Intensity of continuous blue-light-emitting-diode radiation- 10 mW (milliwatt)
Intensity of continuous red-light-emitting-diode radiation- 5 mW (milliwatt)
Intensity of continuous IR-light-emitting-diode radiation - 50 mW (milliwatt)
Magnetic induction - 30 mT (millitesla)
Guaranty for device 5 years as from the date of sale!
489,7
101070 Device "MILTA-F-5-01" (SPORT) Adjustable pulse power of laser radiation 0-60 W.
Intensity of continuous IR-light-emitting-diode radiation - 100 mW (milliwatt)
Magnetic induction - 30 mT (millitesla)
Guaranty for device 5 years as from the date of sale!
434,92
101366 Device "MILTA-F-5-01" (BIO) 0-18 W Adjustable pulse power of laser radiation 0-18 W. Intensity of continuous blue-light-emitting-diode radiation- 10 mW (milliwatt) Intensity of continuous red-light-emitting-diode radiation- 5 mW (milliwatt) Intensity of continuous IR-light-emitting-diode radiation - 50 mW (milliwatt) Magnetic induction - 30 mT (millitesla) Guaranty for device 5 years as from the date of sale! 577,68
101367 Device "MILTA-F-5-01" (BIO) 0-22 W Adjustable pulse power of laser radiation 0-22 W. Intensity of continuous blue-light-emitting-diode radiation- 10 mW (milliwatt) Intensity of continuous red-light-emitting-diode radiation- 5 mW (milliwatt) Intensity of continuous IR-light-emitting-diode radiation - 50 mW (milliwatt) Magnetic induction - 30 mT (millitesla) Guaranty for device 5 years as from the date of sale! 673,96
 
Lightguide nozzles and complete equipment to devices "MILTA-F-5-01"
 
101035 Set of nozzles for otorhinolaryngology 5 pcs. different kinds (NoNo 4, 7, 13, 14, 15). 102,92
101039 Lightguide nozzle No4 Otorhinolaryngology for conduction of laser radiation to tonsils 24,9
101042 Lightguide nozzle No7 Dermatology, cosmetology and hygiene of procedures 11,62
101048 Lightguide nozzle No13 Otorhinolaryngology for conduction of laser radiation to tonsils 24,9
101049 Lightguide nozzle No14 Otorhinolaryngology for endo-auricular intervention and conduction of laser radiation to tympanic membrane and for intranasal intervention in pediatrics 24,9
101050 Lightguide nozzle No15 Otorhinolaryngology for intranasa intervention and in pediatrics 24,9
101051 Proper eye protection "BIOLASER" Frame googles for protection from laser radiation. Modern design, adjustable arms. IR, red, green, blue, ultraviolet irradiation. 32,37
101053 Proper eye protection for patient Light and convenient opaque glasses made from plastic. 29,05
101071 Accumulator Spare accumulator for devices "MILTA-F-5-01" (), "MILTA-F-5-01" (BIO), "MILTA-F-5-01" (SPORT) 8,3
101072 Charging unit Charging unit (network adapter) for devices "MILTA-F-5-01" (), "MILTA-F-5-01" (BIO), "MILTA-F-5-01" (SPORT) 10,79
 
Intravenous laser blood irradiation
 
 
Devices for intravenous laser blood irradiation"MILTA-F-8-01"
 
101174 MILTA-VLOK+LT Device MILTA-F-8-01 (5-7 W) for laser therapy in set with ancillary emitting terminal DT-VLOK for intravenous laser blood irradiation (0,63 micrometer, 1,5 mW) 566,06
101175 MILTA-VLOK+NLOK Device MILTA-F-8-01 (7-9 W) in set with ancillary emitting terminal DT-VLOK (0,63 micrometer, 1,5 W) and KT-2 (7-9 W) for intravenous and percutaneous blood irradiation: 693,88
 
Ancillary emitting terminals for intravenous laser blood irradiation to devices "MILTA-F-8-01"
 
101027 DT- VLOK Intensity of continuous red (0,63 micrometer) laser radiation - 2,5 mW (1,5 mW at the exit from lightguide) 146,08
101028 DT- VLOK- M Intensity of continuous red (0,63 micrometer) laser radiation - 30 mW (15 mW at the exit from lightguide) 411,68
 
Hardware systems on the base of laser physiotherapeutic devices
 
 
Equipment for general physiotherapy on the base of device "MILTA-F-8-01"
 
111000 Equipment for general physiotherapy on the base of device MILTA-F-8-01 Set contents:
Device "MILTA-F-8-01" 7-9 W,
Ancillary emitting terminal DT-2,
Ancillary emitting terminal (laser shower),
Set of nozzles No1,
Proper eye protection for doctor,
proper eye protection for patient
1072,94
 
Equipment for arthrology and neurology on the base of device "MILTA-F-8-01"
 
111001 Equipment for arthrology and neurology on the base of device MILTA-F-8-01 Set contents: Device "MILTA-F-8-01" 9-12 W,
ancillary emitting terminalKT-3,
Ancillary emitting terminal (laser shower),
Ancillary emitting terminal DT-VLOK,
Ancillary terminal of extremely high-frequency-ND,
Proper eye protection for doctor,
proper eye protection for patient
1666,54
 
Equipment for urinology and gynecology on the base of device "MILTA-F-8-01"
 
111002 Equipment for urinology and gynecology on the base of device MILTA-F-8-01 Set contents:
Device "MILTA-F-8-01" 9-12 W,
ancillary emitting terminal KT-3,
Ancillary emitting terminal (laser shower),
Matrical intracavitary termina MVT,
set of nozzles urinology and proctology,
set of nozzles for obstetric and gynecology,
Proper eye protection for doctor,
proper eye protection for patient,
Support-holder
1350,83
 
Laser therapy equipment "MILTA - K"
 
101003 Device "MILTA-F-8-01"
9-12 W
Double-tubes device for magnetic-laser therapy with base terminal
Pulse power of IR-laser radiation 912 W
Intensity of continuous IR-light-emitting-diode radiation- 100 mW (milliwatt)
Magnetic induction - 50mT (millitesla)
602,58
101021 KT-3
9-12 W
Pulse power of IR-laser radiation912 W
Intensity of continuous red-light-emitting-diode radiation - 50 mW (milliwatt)
Magnetic induction - 50mT (millitesla)
177,62
101178 Device for vacuum massage "Matrix-VM" It is intended for carrying out procedures of vacuum and laser - vacuum massage. 332
101241 Guidance manual Cosmetology Geynits A.V., Moskvin S. B. Laser therapy in cosmetology and dermatology, M., 2010 16,6
101243 Guidance manual
Laser - vacuum massage
Moskvin S.V., etc. Laser - vacuum massage by the device LAZMIK in medicine and cosmetology, M, 2011, 104 p. 4,98
401001 Set of nozzles Set of specialized cosmetology nozzles (7 pcs.) 149,4
 
Extremely high-frequency therapy
 
 
Terminal of extremely high-frequency therapy to devices "MILTA-F-8-01"
 
101029 Terminal of extremely high-frequency therapy Millimeter waves of extremely high-frequency 7.1, 5.6, 4.9 mm (millimeter).
Power flux density 4-12 mW/cm2
544,48














Feedback